  • Place of Origin: China
  • Brand Name: Xingjin
  • Standard of Examination: GB25972-2010
  • Certification: CAL, CMA, CNAS, ILAC-MRA, CCC
  • Storage Pressure: 4.2Mpa or 5.6Mpa
  • Capacity of Cylinder: 70L, 90L, 100L, 120L, 150L, 180L
  • Zone Management: Single or Multiple
  • Pattern of Extinguishing: Enclosed Flooding
  • Agent: FM200 (HTC-227ea or Heptafluoropropane)
  • Actuation: Automatic or Manual

PRODUCT Description

Description

FM200 (HTC-227ea) is a kind of colorless and tasteless and non-corrosive and electricity-insulating gas without residue and pollution after extinguishing. And ODP of it is zero. It is a friendly-environment gas to be used for extinguishing. Also, because of such feature, it can be used in special place where electrical fire is easy to happen.

1. Clean gas, colorless and tasteless and non-corrosive

2. Electric insulation, utilization for extinguishing of electrical combustion

3. No residue and pollution inside protection zone

4. No damage to ozone layer

Combined with extinguishing device and electronic accessories, the whole system can be actuated automatically. It can monitor the situation of protective region through detectors and then it can also start the extinguishing device through solenoid actuator automatically. So the whole system can achieve automation totally. Therefore, it can avoid that there is no one who notice the fire when it happens and it also saves much money for employment to supervise the protective area.

1. Totally automatic system

2. Accurate control of protection zone

3. No need for employment of monitor staff

4. Manual or electromagnetic manipulation and mechanical manipulation

Management of Multiple zones is also in the safe control of the whole system. We can use one system to protect multiple zones through selective valves. It can let the whole system alternative aiming at different protective zone. Agent can be discharged into where the fire happens. It will be very efficient to put out fire in short time. One thing that need to mention, is that a little room should be prepare to be as storage space for the whole system.

1. Multiple management in the control of the whole system

2. Agent quantity for biggest zone is enough to protect all zones through selector valves

3. Direct target to expensive machine or delicate device

4. Short time discharge of extinguishing agent

5. Preparation for storage room

6. Space confirmation of placement for cylinder group

Applications

Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.

The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.

Compositions

Piped network type of fm200 automatic fire suppression system is mainly composed by three parts. Extinguishing devices and pipe fittings and electrical accessories.

Extinguishing devices are such things, like cylinder to fill and store fm200, frame and driving device (nitrogen cylinder) to trigger the storage cylinder to discharge agent and so on.

Pipe fittings are those conduits to connect extinguishing device and guide agent into protective zone, like high pressure galvanized steel pipe and flange and elbow and so on.

Electrical accessories are those things which are used to detect and monitor whole protective area and control whole system, also warn people to evacuate and prevent from fire expansion.

These integrated three parts will be efficient to detect and supervise and alarm and extinguish fire automatically.

Here attached below is complete composition of whole system.

Compositions

Competitive Advantage

In terms of description of agent, one of its competent advantages is that it can be used for all kinds of class fires except metal fire. And it is clean agent. There is no residue and pollution after extinguishing.

Another one is that fm200 extinguishing system is special for critical assets or device. It will have no damage for your property. Relatively, it is cheap and effective to be chosen as fire suppression system.

It is very efficient for you to protect your possession. Since it is a system, it include extinguishing device to put out fire at short time, specially, shorter than 10 second. It means all agent will be discharged in so short time. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minute. It means when fire happens, there is enough time left to evacuate people from hazardous place.

It can let multiple zones are protectively in the control of one system. Then it will save much money for big and multiple zones.

Working Principle

Here is the illustration of working principle to whole system.

Working Principle

Simulated Diagram

Below attached is one mimic diagram of piped network type of fm200 automatic fire suppression system.

Simulated Diagram

Simulated Diagram

Specification

No.

Specification

Technical Parameter

1

Filling Pressure

4.2Mpa

5.6Mpa

2

Scale of Protective Region for One Zone

Area: Max Single-zone is 800m²

VolumeMax Single-zone is 3600m³

3

Spraying Time

≤10s

4

Filling Density

≤950kg/m3

≤1080kg/m3

5

Power

DC24V/1.6A

6

Nitrogen Pressure of Driving Device

6.0±1.0Mpa(20℃)

7

Condition of Reserving Room for Container

Temperature: -10~50℃

Relative Humidity: ≤97%

8

Max Working Pressure

5.3Mpa

8.0Mpa

9

Min Working Pressure

4.2Mpa

4.6Mpa

Composition

Pipe Network Composition

1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing fm200 agent.

2. Electrical parts: smoke detector, heat detector, bell etc.

3. Pipe fittings: conduit, connector, elbow, flange etc.

Cabinet Composition

1. Mechanical parts: cylinder with container valve, cabinet, high pressure hose etc.

2. Electrical parts: smoke detector, heat detector, bell etc.

Suspension Composition

1. Mechanical parts: tank with container valve, nozzle, solenoid valve etc.

2. Electrical parts: smoke detector, heat detector, bell etc.

Competitive Advantage

For Different Agents

1. Clean gas agent

2. Colorless, tasteless, low toxicity, and non-conductive

3. No residue or oily deposits

4. Small storage space and easily pressurized in cylinder

5. Compliance with environmental protection requirement

6. Large range of application area

7. Perfect protection of apparatus or zones

8. No damage to equipment or device

9. Simple disposal after ventilation

For Different Products

Pipe network fm200 system: multiple management along with selector valve, balanced spraying in big zone through pipeline, management of different layer, overall protection.

Cabinet fm200 system: management of big zone, simple integration, direct spraying effect in protection zone, efficient fire suppression.

Hanging fm200 system: perfect choice for solo zone, least occupation in protective zone, simple and fast installation.

Pipe Network

1. Management of multiple zones

2. Efficient fire protection in big region

3. Less occupation in fire-controlled space

4. Relatively cheap price than cabinet or hanging type if zone is big and multiple

Pipe Network Selection Needs Attention

1. Choice for storage room, including ambient environment and volume

2. Design of pipeline, including placement of conduits and connection

3. Installation, integration of each parts and connection between parts

Cabinet

1. Effective firefighting in relatively small region

2. Simple assembly of device without pipeline

3. No extra space to store device

Cabinet Selection Needs Attention

1. One cabinet or multiple cabinet type fm200 for one zone

2. Enough space in protective region to place it, such as corner or edge of wall

3. Attention to compare height of cabinet and room

Hanging

1. Small but effective

2. Extremely simple installation

3. Little space for placement of it

4. Hanging on the ceiling or wall

5. Low cost for little protective zone

Hanging Selection Needs Attention

1. Few devices can be connected together in one room.

2. Ceiling should be fastened and firm

Payment & Shipping Terms

Minimum Order Quantity: 1 set system

Price: Negotiation

Payment Terms: L/C, T/T, Western Union, Paypal, etc.

Supply Ability: 300 sets per month

Delivery Time: 10-15 working Days after payment or receipt of L/C

Packaging Details: Plywood Case

INQUIRY

Contact Us

contact-email
contact-logo

Guangzhou Xingjin Fire Equipment Co., Ltd.

We provide customers with quality products and services.

If you would like to leave us a comment please go to contact us

© 2019 Guangzhou Xingjin Fire Equipment Co., Ltd. All rights received.

  • Home

    Home

  • Tel

    Tel

  • Email

    Email

  • Share

  • Contact

    Contact